Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Odontology ; 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38526626

ABSTRACT

This study evaluated long-term effectiveness UV functionalised short implants (≤ 6 mm) placed in the posterior segments of the atrophied maxilla. The study included 47 patients from 2018 to 2023 (aged 27 to 56 years, 24 women and 23 men) without any systemic diseases, with unilateral/bilateral missing teeth and vertical atrophy of the posterior maxillary area. Total installed were 64 short UV-functionalized implants and 62 standard implants over 10 mm in length in segments maxilla with sufficient bone parameters. Clinical, laboratory and cone beam computed tomography (CBCT) methods were used to plan implant therapy. The clinical indices included the following parameters: ISQ, MBL, OHIP-G scale. For short implants, the median ISQ at placement was 62.2 for primary stability and the median ISQ at 5 months was 69.6 ISQ. For standard implant, the mean ISQ at placement was 64.3 ISQ, and ISQ after 5 months was 71.6 ISQ. After 6 months mean MBL short implants 0.87 mm, after 1 year 1.13 mm, after 5 years was 1.48 mm. After 6 months mean MBL standard implants 0.84 mm, after 1 year 1.24 mm, after 5 years was 1.58 mm. Mean OHIP-G scores-patients satisfaction with the implant at 4.8 ± 0.3, satisfaction with the operation 4.6 ± 0.4; satisfaction with prosthetics 4.7 ± 0.5. Cumulative success rate 5 years short implants was 96.7%, standard implants was 97.4%, and prosthesis cumulative survival rate was 97.2%. Short ultraviolet functionalized implants used in the posterior resorbed segment of maxilla have been shown to be a reliable alternative to sinus lift, demonstrating fewer complications, reduction in the number of additional surgical interventions and showed satisfactory long-term survival.

2.
Quintessence Int ; 54(10): 868, 2023 11 28.
Article in English | MEDLINE | ID: mdl-38015498

ABSTRACT

The following amendments are made to the published article: Quintessence Int 2022;53:690-696; First published 17 August 2022; doi: 10.3290/j.qi.b3095013.

3.
J Maxillofac Oral Surg ; 22(Suppl 1): 64-75, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37041958

ABSTRACT

Objectives: The purpose of this study was to evaluate clinical results of immediate loading UV-photofunctionalized dental implants placed using guided surgery in patients with completely edentulous mandible. Material and Methods: In this study, 58 fully edentulous patients were treated with immediate loading implant-supported mandibular prostheses. All patients underwent a thorough clinical examination according to the generally accepted scheme; qualitative and quantitative parameters of the jaw bones patients were diagnosed with cone beam computerized tomography (CBCT). Surgical templates modeled in the 3 Shape software were made from biocompatible polymeric materials and provided with depth-calibrated drill sleeves for preparing osteotomies using a 3D printer (Stratasys). Before short implant placement, ultraviolet functionalization of implant surfaces was performed by UV Activator YWJ-QSY001 (Foshan, Wenjian Medikal Enstriman) in the device for 20 s. After flapless surgery, implant sockets were prepared with guided surgery and implants were placed through the sleeves of the surgical template tightening torque of 35-45 Ncm. An implant-supported temporary prosthesis made of acrylic resin was installed 6 h after implantation. Final dental prosthetics was performed 2 months after implant placement.The patients had 128 short (length 5-6 mm, diameters 4,5-5 mm) and 256 implants with length greater than 10 mm in bone segments with sufficient bone parameters. The following parameters were assessed: implant success, prosthetics survival and changes in peri-implant marginal bone loss (MBL). Results: During a clinical examination, no serious biological or prosthetic complications have been reported. The esthetic result evaluated from patients was excellent. The mean ISQ of short implants was 69.2 ± 8 for primary stability at implant placement and 73.6 ± 4 ISQ after 3 months. The mean of implants with length greater than 10 mm was 71,2ISQ at implant placement, respectively, and 75,6 ISQ after 3 months. After 3 months of prosthetic loading for short implants marginal bone loss (MBL) 0.74 mm, after 1 year of MBL 11.21 mm, after 5 years of MBL 1,37 mm, for implants with length greater than 10 mm after 3 months of MBL 0.72 mm, after 1 year of MBL 1.19 mm and after 5 years of MBL 1.35. There was no statistically significant difference in clinical indices between short and standard implants. After 5 years of follow-up, stable levels of bone tissue around the implants and healthy tissues around the implants were recorded, and postoperative occlusal function was favorable. The success rates of the short implants in maxilla were 95.5%, and the success rates of the short implants in mandible were 98.7%. The success rates of the implants with length greater than 10 mm in maxilla were 97.8%, and the success rates of the implants with length greater than 10 mm in mandible were 98.8%. Conclusion: Computer-guided implant surgery and immediate loading of UV-photofunctionalized implants in patients with completely edentulous mandible are a predictable and effective method with a minimum rehabilitation period.

4.
Quintessence Int ; 53(8): 690-696, 2022 Aug 17.
Article in English | MEDLINE | ID: mdl-35674172

ABSTRACT

OBJECTIVE: The aim of the study was to assess the long-term prognosis of short implants (5 to 6 mm) placed in the posterior region of the atrophic mandible. METHOD AND MATERIALS: The study included 81 patients with severe vertical atrophy of the bone in the posterior region. The patients had 248 short implants (5 to 6 mm) implants placed in the mandibular posterior region and 256 implants with length greater than 10 mm in the mandibular anterior region. Analysis of implant and prosthesis failures, cumulative survival rate, and marginal bone loss was determined at 1 year and 5 years of follow-up (58 ± 7 months). RESULTS: Mean marginal bone loss after 1 year of prosthetic loading was 0.74 mm for short implants and 0.72 mm for implants with length greater than 10 mm; after 5 years of prosthetic loading this was 1.27 mm for short implants and 1.31 mm for implants with length greater than 10 mm. Of 248 short implants (5 to 6 mm), six failed: four due to peri-implantitis and two due to lack of osseointegration (early rejection). Of 256 implants with length greater than 10 mm, five failed: three due to peri-implantitis and two due to lack of osseointegration (early rejection). On average, over the observation period (58 ± 7 months), the 5-year cumulative implant survival rate was 97.8% in short implants, and 98.1% in longer implants; the prosthesis cumulative survival rate was 98.2%. CONCLUSIONS: Based on the results, it was concluded that the prognosis of the use of short implants for prosthetics in the posterior resorbed mandible can be considered favorable and reasonable.


Subject(s)
Alveolar Ridge Augmentation , Dental Implants , Peri-Implantitis , Alveolar Ridge Augmentation/methods , Atrophy/pathology , Dental Implantation, Endosseous/methods , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Follow-Up Studies , Humans , Mandible/surgery , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...